Appearance |
|
Model |
PEN-T10A |
PEN-R700A |
PEN-M5A |
Type |
Through beam |
Diffuse reflection |
Retro reflection |
Sensing distance |
10 m |
700 mm |
0.1 ~ 5 m |
Sensing object |
Ø 20 mm
(opaque body) |
200 x 200 ㎜
(White non- glossy paper) |
Ø 60 mm
(opaque body) |
Power Supply voltage |
24 – 240 V 50 Hz / 60 Hz AC ± 10 % |
Power consumption |
Emitter:max 1W
Receiver:max 2W |
max 2 W |
Operation mode |
Light ON / Dark ON ※ selectable by mod V/R |
Sensitiviry ad |
– |
Built-in the sensitivity
control V/R |
Control output |
Relay output (Contact composition 1a,1b)capacity : 30 V DC 5 A / 250 V AC 5 A |
Resistance load life expectancy – min 100 thousand time |
|
Response time |
max 20 ms |
Response range |
– |
within 15% of
detect range |
– |
Light source |
infrared rays LED(alteration) |
Material |
Case : Heat resistance ABX, Lens : P.C |
Connection method |
Cable extended type (Number of wire : 5P, Diameter : Ø 6 ㎜, Length : 2 ㎜) ※ Emitter 2P |
Ambient light |
sun light : 11000 Lux below, Incandescent lamp : 3000 Lux below |
Ambient temperature |
-20 ~ 65 °C (surrounding storge temperature : -25 ~ 70 °C) |
Ambient humidity |
35 ~ 85 % RH (with no condensation) |
Dielectric Strenght |
AC 1000 V 1 minute |
Insulation resistance |
20MΩ Min. (At 500V DC between code and case, adjusting switch and case |